Published July 2015
| Version v1
Journal article
Result of UT verification test for stainless steel through weld deposit. 2nd report
- 1. Kansai Electric Power Co., Inc., Takahama, Fukui (Japan)
- 2. Mitsubishi Heavy Industries, Ltd., Tokyo (Japan)
Description
Japanese code for ultrasonic testing in-service inspection, named JEAC 4207, allows inspection through weld metal, in case that some factors, such as weld crown or other structures, disturb scanning. The applicability of through weld metal inspection had been reported with BWR piping. This paper will be technical basis of applicability of through weld metal inspection for PWR piping, which is thicker and has factor hardens inspection. The data successfully shows the capability for detection and sizing by through weld metal inspection. (author)
Additional details
Publishing Information
- Journal Title
- Hozengaku
- Journal Volume
- 14
- Journal Issue
- 2
- Journal Page Range
- p. 81-88
- ISSN
- 1348-7795
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 47051537
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- APERTURES; CASTING; CRACKS; DEPTH; EFFICIENCY; FATIGUE; FILLER METALS; IN-SERVICE INSPECTION; PERFORMANCE TESTING; PIPES; PWR TYPE REACTORS; STRESS CORROSION; THICKNESS; ULTRASONIC TESTING; WELDED JOINTS
- Descriptors DEC
- ACOUSTIC TESTING; CHEMICAL REACTIONS; CORROSION; DIMENSIONS; ENRICHED URANIUM REACTORS; FABRICATION; INSPECTION; JOINTS; MATERIALS TESTING; MECHANICAL PROPERTIES; NONDESTRUCTIVE TESTING; OPENINGS; POWER REACTORS; REACTORS; TESTING; THERMAL REACTORS; TUBES; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 5 refs., 12 figs., 4 tabs.