Published 1990 | Version v1
Report Open

Calculational analysis of errors for various models of an experiment on measuring leakage neutron spectra

Description

Analysis is made for the effect of mathematical model accuracy of the system concerned on the calculation results using the BRAND program system. Consideration is given to the impact of the following factors: accuracy of neutron source energy-angular characteristics description, various degrees of system geometry approximation, adequacy of Monte-Carlo method estimation to a real physical neutron detector. The calculation results analysis is made on the basis of the experiments on leakage neutron spectra measurement in spherical lead assemblies with the 14 MeV-neutron source in the centre. 4 refs.; 2 figs.; 10 tabs

Availability note (English)

MF available from INIS under the Report Number.

Files

22058345.pdf

Files (546.4 kB)

Name Size Download all
md5:3b89d4d9bd709758718b118b8b47f68d
546.4 kB Preview Download

System files (39.9 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Расчетный анализ погрешностей различных моделей эксперимента по измерению спектров нейтронов утечки

Publishing Information

Imprint Pagination
19 p.
Report number
FEI--2087