The value of flat-detector computed tomography during catheterisation of congenital heart disease
Creators
- 1. Friedrich-Alexander University Erlangen-Nuernberg, Department of Pediatric Cardiology, Erlangen (Germany)
- 2. University Hospital Erlangen, Department of Pediatric Cardiology, Erlangen (Germany)
- 3. University Hospital Erlangen, Department of Congenital Heart Surgery, Erlangen (Germany)
- 4. University Hospital Erlangen, Department of Cardiology, Erlangen (Germany)
Description
To analyse the diagnostic utility of flat-detector computed tomography imaging (FD-CT) in patients with congenital heart disease, including the value of image fusion to overlay three-dimensional (3D) reconstructions on fluoroscopic images during catheter-based interventions. We retrospectively analysed 62 consecutive paediatric patients in whom FD-CT was used during catheterisation of congenital heart disease. Expert operators rated the clinical value of FD-CT over conventional fluoroscopic imaging. Added radiation exposure and contrast medium volume were evaluated. During a 12-month period, FD-CT was performed in 62 out of 303 cardiac catheterisations. Median patient age was 3.5 years. In 32/62 cases, FD-CT was used for diagnostic purposes, in 30/62 cases it was used in the context of interventions. Diagnostic utility was never rated as ''misleading''. It was classified as ''not useful'' in six cases (9.7%), ''useful'' in 18 cases (29.0%), ''very useful'' in 37 cases (59.7%) and ''essential'' in one case (1.6%). The median added dose-area product was 111.0 μGym2, the required additional quantity of contrast medium was 1.6 ml/kg. FD-CT provides useful diagnostic information in most of the patients investigated for congenital heart disease. The added radiation exposure and contrast medium volume are reasonable. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-011-2214-3Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 21
- Journal Issue
- 12
- Journal Page Range
- p. 2511-2520
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43006806
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; CLINICAL TRIALS; COMPUTERIZED TOMOGRAPHY; CONGENITAL DISEASES; CONTRAST MEDIA; CORONARIES; DIAGNOSIS; FLUOROSCOPY; HEART; PEDIATRICS; RADIATION DETECTORS; RADIATION DOSES
- Descriptors DEC
- ARTERIES; BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TESTING; TOMOGRAPHY