Published 1981 | Version v1
Report Open

Study of the spatial resolution of a large proportional chamber with the use of the analog readout of cathode information

Description

Results of a study on the detection accuracy of particle coordinates in a large proportional chamber using the cathode information readout are presented. The width of cathode stripts was 18 mm and the anode to cathode distance 7 mm. The avalanche coordinates were determined by the distribution of charge induced on the cathode stripts. The detection accuracy was estimated by the difference of the avalanche coordinates obtained on different cathodes. The accuracy of detection of the avalanche coordinates was 0.6 mm, 1.4 mm, and 4.8 mm at a strip width of 18 mm, 36 mm, and 54 mm, respectively. The cathode strips of 36 mm and 54 mm wide were made by connecting two and three strips 18 mm in width. The measurements have been performed using an X-ray 106Ru source

Availability note (English)

MF available from INIS under the Report Number.

Files

13675921.pdf

Files (167.7 kB)

Name Size Download all
md5:cc8a70a884c86161709dd6c975ed902d
167.7 kB Preview Download

System files (24.5 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Исследование пространственного разрешения большой пропорциональной камеры с аналоговым считыванием информации с катодов

Publishing Information

Imprint Pagination
6 p.
Report number
JINR-R--13-81-554

Optional Information

Notes
1 ref.; 4 figs.