Published February 2005 | Version v1
Journal article

Evaluation of a conjugate view method for determination of kidney uptake

  • 1. Yonsei University College of Medicine, Seoul (Korea, Republic of)
  • 2. Research Institute of Raiological Science, Seoul (Korea, Republic of)

Description

In order to obtain better quantitation of kidney uptake, this study is to evaluate a conjugate view method (CVM) using a geometric mean attenuation correction for kidney uptake and to compare it to Gate's method. We used a Monte Carlo code, SIMIND and a Zubal phantom, to simulate kidney uptake. SIMIND was both simulated with or without scatter for the Zubal phantom. Also a real phantom test was carried out using a dual-head gamma camera. The activity of 0.5 mCi was infused into two small cylinder phantoms of 5 cm diameter, and then, they were inserted into a cylinder phantom of 20 cm diameter. The results by the CVM method were compared with ideal data without both of attenuation and scatter and with Gate's method. The CVM was performed with or without scatter correction. The Gate's method was performed without scatter correction and it was evaluated with regards to 0.12 cm-1 and 0,15 cm-1 attenuation coefficients. Data were analyzed with comparisons of mean counts in the regions of interest (ROI), profiles drawn over kidney images and linear regression. Correlation coefficients were calculated with ideal data, as well. In the case of the computer simulation, mean counts measured from ideal data, the CVM and the Gate's method were (right: 998 ± 209, left: 896 ± 249), (right: 911 ± 207, left: 815 ± 265), and (right: 1065 ± 267, left: 1546 ± 267), respectively. The ideal data showed good correlation with the CVM and the correlation coefficients of the CVM, Gate's method were (right: 0.91, left: 0.93) and (right: 0.85, left: 0.90), respectively. The conjugate view method using geometric mean attenuation correction resulted in better accuracy than the Gate's method. In conclusion, the conjugate view method independent of renal depths may provide more accurate kidney uptake

Additional details

Publishing Information

Journal Title
Korean Journal of Nuclear Medicine
Journal Volume
39
Journal Issue
3
Series
23 refs, 7 figs
Journal Page Range
p. 191-199
ISSN
1225-6714

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
38057750
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ATTENUATION; COMPUTERIZED SIMULATION; CORRECTIONS; IMAGES; KIDNEYS; MONTE CARLO METHOD; UPTAKE
Descriptors DEC
BODY; CALCULATION METHODS; ORGANS; SIMULATION