Published 1982 | Version v1
Report Open

Automated-process gas-chromatograph system for use in accelerated corrosion testing of HTGR core-support posts

Description

An automated-process gas chromatograph is the heart of a gaseous-impurities-analysis system developed for the Oak Ridge National Laboratory Core Support Performance Test, at which graphite core-support posts for high-temperature gas-cooled fission reactors are being subjected to accelerated corrosion tests under tightly controlled conditions of atmosphere and temperature. Realistic estimation of in-core corrosion rates is critically dependent upon the accurate measurement of low concentrations of CO, CO2, CH4, H2, and O2 in the predominantly helium atmosphere. In addition, the capital and labor investment associated with each test puts a premium upon the reliability of the analytical system, as excessive downtime or failure to obtain accurate data would result in unacceptable costs and schedule delays. After an extensive survey of available measurement techniques, gas chromatography was chosen for reasons of accuracy, flexibility, good-performance record, and cost

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE83001949.

Files

14746895.pdf

Files (142.0 kB)

Name Size Download all
md5:c2418b12adff265403ed8dc0d820439d
142.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
CONF-821033--2

Conference

Title
Instrumentation Society of American international conference.
Dates
18 - 21 Oct 1982.
Place
Philadelphia, PA (USA).