Published July 1988
| Version v1
Report
Restricted
Method for consequence calculations for severe accidents
Description
This report was commissioned by the Swedish State Power Board. The report contains a calculation of radiation doses in the surroundings caused by a theoretical core meltdown accident at Forsmark reactor No 3. The accident sequence chosen for the calculating was a release caused by total power failure. The calculations were made by means of the PLUCON4 code. Meteorological data for two years from the Forsmark meteorological tower were analysed to find representative weather situations. As typical weather, Pasquill D was chosen with a wind speed of 5 m/s, and as extreme weather, Pasquill F with a wind speed of 2 m/s. 23 tabs., 37 ills., 20 refs. (author)
Availability note (English)
Also available from Risoe Library, DK-4000 Roskilde.
Files
Additional details
Additional titles
- Subtitle (English)
- Release from Forsmark 3 caused by total power failure
- Original title (Danish)
- Metode for konsekvensberegninger for store havarier
- Original subtitle (Danish)
- Udslip fra Forsmark 3 foraarsaget af totalt elbortfald og tidlig spraengpladeaabning.
Publishing Information
- ISBN
- 87-550-1435-6
- Imprint Pagination
- 68 p.
- Report number
- RISO-M--2721
INIS
- Country of Publication
- Denmark
- Country of Input or Organization
- Denmark
- INIS RN
- 19095429
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPUTERIZED SIMULATION; DESIGN BASIS ACCIDENTS; ENVIRONMENTAL IMPACTS; FORSMARK-3 REACTOR; MELTDOWN; METEOROLOGY; P CODES; RADIATION DOSES; WIND
- Descriptors DEC
- ACCIDENTS; BWR TYPE REACTORS; COMPUTER CODES; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SIMULATION; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Contract/Grant/Project number
- Contract BIT-550540