Published 1976 | Version v1
Miscellaneous Open

The possibility to determine the deepth of the defects based on radiographs by means of standards

Description

Calibration standards have been developed and a method proposed which allow to measure directly the depth of defects. Some experiments carried out with a 192Ir source are described

Abstract (French)

Des etalons ont ete mis au point et une methode est proposee qui permettent de mesurer directement la profondeur des defauts. Quelques experiences effectuees avec une source de 192Ir sont decrites

Files

8313099.pdf

Files (238.9 kB)

Name Size Download all
md5:3cc75a52f88a2d9f6172f3909f3bb396
238.9 kB Preview Download

Additional details

Additional titles

Original title (French)
Possibilite de determiner la profondeur des defauts basee sur l'emploi de films radiographiques, au moyen d'etalons

Publishing Information

Imprint Pagination
8 p.
Report number
INIS-mf--3553

Conference

Title
8. World conference on nondestructive testing.
Dates
6 Sep 1976.