Improvement of the qualitative and quantitative detection of simultaneously present fluorescent tracers by systematic sample treatment
Creators
Description
The selective instrumental detection of individual fluorescent tracers in mixtures containing further fluorescent dyes is limited by spectral interferences. Therefore additional separations or other suitable procedures have to be included into the analytic technique. With the method described below, the respective tracer to be detected remains with its initial concentration in the sample and is analysed under the appropriate conditions, whereas the interfering tracers are separated or suppressed. The techniques applied for this base on the facts that 1) the fluorescence intensity of the tracers varies differently when the pH-value changes; 2) the tracers show different absorption behaviour and 3) they provide different degrees of light sensitivity. The procedures permit for example to detect uranin when eosin is present in a higher concentration or to detect eosin when amidorhodamin G is present. (orig.)
Abstract (German)
Der selektive instrumentelle Nachweis von einzelnen Fluoreszenztracern in Gemischen mit weiteren Fluoreszenztracern wird durch die Ueberlagerung der Spektren begrenzt. Deshalb muessen zusaetzliche Trennungen oder andere geeignete Massnahmen in die Analytik einbezogen werden. Beim hier beschriebenen Vorgehen wird der jeweils zu bestimmende Tracer in seiner Ausgangskonzentration in der Probe belassen und unter geeigneten Bedingungen analysiert, waehrend die stoerenden Tracer abgetrennt oder unterdrueckt werden. Die dafuer eingesetzten Techniken beruhen auf der unterschiedlichen Aenderung der Fluoreszenzintensitaet der Tracer bei pH-Aenderungen, auf ihrem unterschiedlichen Adsorptionsverhalten und auf ihrer unterschiedlichen Lichtempfindlichkeit. Mit den Verfahren ist es z.B. moeglich, Uranin bei Anwesenheit von Eosin in hoeherer Konzentration oder Eosin bei Anwesenheit von Amidorhodamin G nachzuweisen. (orig.)
Files
Additional details
Additional titles
- Original title (German)
- Verbesserung des qualitativen und quantitativen Nachweises von nebeneinander vorliegenden Fluoreszenztracern durch systematische Probenbehandlung
Publishing Information
- Imprint Title
- Contributions to hydrological tracer methods and their application
- Imprint Pagination
- 475 p.
- Journal Page Range
- p. 1-12.
- Report number
- GSF-R--290
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 14775554
- Subject category
- S58: GEOSCIENCES;
- Descriptors DEI
- ADSORPTION; EOSIN; FLUORESCEIN; FLUORESCENCE SPECTROSCOPY; GROUND WATER; HYDROLOGY; PH VALUE; QUANTITY RATIO; RHODAMINES; SENSITIVITY; TRACER TECHNIQUES
- Descriptors DEC
- AMINES; AROMATICS; CARBOXYLIC ACIDS; DYES; EMISSION SPECTROSCOPY; HETEROCYCLIC ACIDS; HETEROCYCLIC COMPOUNDS; HYDROGEN COMPOUNDS; HYDROXY ACIDS; HYDROXY COMPOUNDS; INDICATORS; ISOTOPE APPLICATIONS; ORGANIC ACIDS; ORGANIC BROMINE COMPOUNDS; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; ORGANIC OXYGEN COMPOUNDS; OXYGEN COMPOUNDS; PHENOLS; POLYPHENOLS; REAGENTS; SPECTROSCOPY; WATER
Optional Information
- Notes
- Imprint:Beitraege ueber hydrologische Tracermethoden und ihre Anwendungen.