Selection of radiometric system signals for detection of falling outside the permissible limits of controllable parameter
Creators
Description
Mutual two-dimensional distribution of pairs of radiation registered intensities by falling the controllable parameter outside the permissible limits is studied. It is shown that the above distributions are single-apex asymmetrical ones and ovals to equal probability density elongate with increase in closeness of stochastic bonds between registered intensities. Sharp increase in reliability of close extreme parameters identification is provided for by selection of closely correlated intensities. The additional reliability can be achieved by close to parallel elongation of ovals along their large axes. 4 refs.; 3 figs
Additional details
Additional titles
- Original title (Russian)
- Выбор сигналов радиометрических систем для обнаружения выхода контролируемого параметра за допустимые пределы
Publishing Information
- Journal Title
- Atomnaya Ehnergiya
- Journal Volume
- 78
- Journal Issue
- 5
- Journal Page Range
- p. 315-321.
- ISSN
- 0004-7163
- CODEN
- AENGAB
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 27011381
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCURACY; PATTERN RECOGNITION; PROBABILISTIC ESTIMATION; RADIOMETRIC GAGES; RELIABILITY; SIGNAL DISTORTION; SIGNAL-TO-NOISE RATIO; STOCHASTIC PROCESSES
- Descriptors DEC
- MEASURING INSTRUMENTS