Published February 1987 | Version v1
Report

UPTF test results--first three separate effects tests

  • 1. Kraftwerk Union AG, Erlangen, West Germany

Description

The first separate effect tests were run in the Upper Plenum Test Facility - a 1:1 representation of a PWR primary system. These tests were focusing the simultaneous steam up - and water down flow phenomena at the upper tie plate, the fluid-fluid mixing in the cold leg and downcomer and the counter-current flow conditions of steam and saturated water in a PWR hot leg

Additional details

Publishing Information

Imprint Title
Proceedings of the US Nuclear Regulatory Commission fourteenth water reactor safety information meeting: Volume 4, ECCS [Emergency Core Cooling Systems] rule revision, integral systems testing, separate effects/experiments and analyses, 2D/3D research
Journal Page Range
p. 459-486.
Report number
NUREG/CP--0082-Vol.4

Conference

Title
14. water reactor safety information meeting.
Dates
27-31 Oct 1986.
Place