Seismic analysis of control and safety rod drive mechanism
- 1. Indian Institute of Technology, Chennai (India)
- 2. Indira Gandhi Centre for Atomic Research, Kalpakkam (India)
Description
Control rod and its driving mechanism for a Fast Breeder Reactor is to facilitate safe shutdown of the reactor in case of emergency. A theoretical study on the seismic qualification of control and safety rod driving mechanism is carried out. Earthquake excitations under Operational Basis (ORE) and Safe Shutdown condition (SSE) are considered. The time required for the control rod to reach the bottom position in order to shut down the reaction under excited condition is traced out. The maximum displaced positions and extreme stresses in various parts of the system under excitations are evaluated. The system modeled using beam elements. The connections between different parts are modeled through rigid elements. The interaction between various parts are modeled using GAP elements. (author)
Additional details
Publishing Information
- Publisher
- Allied Publishers Pvt. Ltd.
- Imprint Place
- New Delhi (India)
- ISBN
- 81-7764-415-7
- Imprint Title
- Proceedings of the national seminar on seismic design of nuclear power plants
- Imprint Pagination
- 536 p.
- Journal Page Range
- p. 53-65
Conference
- Title
- National seminar on seismic design of nuclear power plants
- Dates
- 21-22 Feb 2003
- Place
- Chennai (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 34071813
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CONTROL ROD DRIVES; EARTHQUAKES; ELECTROMAGNETS; FBR TYPE REACTORS; FINITE ELEMENT METHOD; REACTOR SAFETY; REACTOR SHUTDOWN; SEISMIC EFFECTS; STRESSES
- Descriptors DEC
- BREEDER REACTORS; CALCULATION METHODS; ELECTRICAL EQUIPMENT; EPITHERMAL REACTORS; EQUIPMENT; FAST REACTORS; MAGNETS; MATHEMATICAL SOLUTIONS; NUMERICAL SOLUTION; REACTOR COMPONENTS; REACTORS; SAFETY; SEISMIC EVENTS; SHUTDOWN
Optional Information
- Notes
- 1 ref., 9 figs., 1 tab.