Published 1996 | Version v1
Book

Analytical studies on the behaviour of nuclear reactor containment

  • 1. Bhabha Atomic Research Centre, Bombay (India). Reactor Safety Div.

Description

A containment system transient analysis code CONTRAN has been developed in Bhabha Atomic Research Centre. The code has been validated against experimental data. Recently, using the code CONTRAN, a large number of analytical case studies have been carried out, to study the influence of various parameters on the pressure transients in a typical containment of Indian PHWRs, following an accident. The details of these studies and results obtained are presented and discussed in this paper. (author). 11 refs., 17 figs., 1 tab

Part of:
Heat and mass transfer 95

Additional details

Publishing Information

Publisher
Tata McGraw-Hill Publishing Company Limited.
Imprint Place
New Delhi (India)
ISBN
0-07-462307-9
Imprint Title
Heat and mass transfer 95
Imprint Pagination
975 p.
Journal Page Range
p. 675-680.

Conference

Title
2. ISHMT-ASME heat and mass transfer conference; 13. national heat and mass transfer conference.
Dates
28-30 Dec 1995.
Place
Surathkal (India).

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
27075634
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
C CODES; CONTAINMENT; HEAT TRANSFER; LOSS OF COOLANT; PARAMETRIC ANALYSIS; PHWR TYPE REACTORS; PRESSURIZATION
Descriptors DEC
ACCIDENTS; COMPUTER CODES; ENERGY TRANSFER; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; REACTOR ACCIDENTS; REACTORS