Published 2004 | Version v1
Book

X-band RF generation test of compact hard X-ray source based on X-band linac

  • 1. National Laboratory of Radiological Sciences, Chiba (Japan)
  • 2. Tokyo Univ., Nuclear Engineering Research Laboratory, Tokai, Ibaraki (Japan)

Description

Compact monochromatic hard X-ray source based on laser-electron collision for dynamic Intravenous Coronary Arteriography (IVCAG) is proposed and designed. X-band linac is introduced to realize remarkably compact system. We have performed design of the compact monochromatic tunable hard X-ray source. Stability of output pulse voltage of the X-band RF modulator with 5 pps, 430 kV is less than 0.1% in rms. Beam aging of the X-band Klystron Toshiba E3768I is finished. High speed RF interlock system for RF aging to protect the RF system from RF breakdown at waveguides is constructed and tested. Response of the interlock is about 350 ns. To install the X-band beam line to UTNL site, redesign of the beam line is performed. (author)

Part of:
Proceedings of the 1st annual meeting of Particle Accelerator Society of Japan and the 29th Linear Accelerator Meeting in Japan

Additional details

Publishing Information

Publisher
Particle Accelerator Society of Japan
Imprint Place
Tokyo (Japan)
Imprint Title
Proceedings of the 1st annual meeting of Particle Accelerator Society of Japan and the 29th Linear Accelerator Meeting in Japan
Imprint Pagination
717 p.
Journal Page Range
p. 245-247

Conference

Title
1. annual meeting of Particle Accelerator Society of Japan; 29. Linear Accelerator Meeting in Japan
Dates
4-6 Aug 2004
Place
Funabashi, Chiba (Japan)

Optional Information

Notes
8 refs., 6 figs.