Published February 1965 | Version v1
Journal article

Separation of americium and some rare earths from lanthanum by reversed phase chromatography

  • 1. Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

Description

Reversed phase column chromatography was applied to the separation of Am, Pr, Pm and Eu from 5 to 110 mg of La carrier after coprecipitation. HDEHP and TOPO-xylene solutions held on kieselguhr were used as the stationary phase and the elutions were carried out with 0.1 to 1 N nitric acid solutions. In the HDEHP system, Am can be separated from the rare earths except from Pr. Am can also be separated from Eu in the TOPO system. (author)

Availability note (English)

Available from DOI: https://doi.org/10.1080/18811248.1965.9732157

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo) (Online)
Journal Volume
2
Journal Issue
2
Journal Page Range
p. 45-50
ISSN
1881-1248

Optional Information

Notes
16 refs., 8 figs., 2 tabs.