Evaluation of the 99Mo contamination in eluates samples generated of 99mTc in a clinic of Recife, Brazil
Creators
- 1. Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)
Description
This study evaluates the 99Mo content in eluates of 99Mo/99m Tc generators, used in a nuclear medicine service in Recife. To do this, were collected eluates samples from 5 elution of 10 different generators using the attenuation method in own nuclear medicine service which provided routine activimeter CRC-127R model, manufactured by Capintec. The samples were measured, and the activities of 99mTc and 99Mo were determined and calculated the MBT (molybdenum break through) for 1st, 3rd, 5th, 7th and 9th elution of each generator. It was observed in a sample the presence of molybdenum in the amount near the limit set by the United States Pharmacopoeia (USP), 0,15μCi/mCi). A second sample presented good high value, more than double the USP limit. The results obtained demonstrate the possibility of finding 99Mo in the eluted solution, which reinforces the need to deploy the control test of the molybdenum content in all elution in quality control programs of service nuclear medicine
Files
46091297.pdf
Files
(118.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:ecfd05e694f5a8041e5419e6929b80ce
|
118.2 kB | Preview Download |
Additional details
Additional titles
- Original title (Portuguese)
- Avaliacao da contaminacoa de 99Mo em amostras de eluatos de geradores de 99mTc em clinica do Recife
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- INIS-BR--15401
Conference
- Title
- 1. Symposium of internal dosimetry applied to nuclear medicine
- Original Conference Title
- 1. Simposio de dosimetria interna aplicada a medicina nuclear
- Acronym
- DOSIMN 2008
- Dates
- 8-11 Apr 2008
- Place
- Recife, PE (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 46091297
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACTIVITY METERS; IMPURITIES; MOLYBDENUM 99; NUCLEAR MEDICINE; QUALITY CONTROL; RADIATION PROTECTION; RADIOISOTOPE GENERATORS; RADIOPHARMACEUTICALS; TECHNETIUM 99
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CONTROL; DAYS LIVING RADIOISOTOPES; DRUGS; EVEN-ODD NUCLEI; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MATERIALS; MEASURING INSTRUMENTS; MEDICINE; METERS; MOLYBDENUM ISOTOPES; NUCLEI; ODD-EVEN NUCLEI; RADIOACTIVE MATERIALS; RADIOISOTOPES; TECHNETIUM ISOTOPES; YEARS LIVING RADIOISOTOPES