Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging
Creators
- 1. Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany)
- 2. Siemens Healthcare, Imaging and Therapy Division, Forchheim (Germany)
- 3. Heidelberg University, Computer Assisted Clinical Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany)
Description
To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm2 removesthe necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63 %/39 % lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-014-3406-4Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 25
- Journal Issue
- 1
- Journal Page Range
- p. 178-185
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 46017864
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; AUDITORY ORGANS; EFFICIENCY; FEASIBILITY STUDIES; IMAGE PROCESSING; ITERATIVE METHODS; RADIATION DOSES; RADIATION HAZARDS; SKELETON; SPATIAL RESOLUTION; X-RAY SOURCES
- Descriptors DEC
- BODY; CALCULATION METHODS; DOSES; HAZARDS; HEALTH HAZARDS; MATHEMATICAL LOGIC; ORGANS; PROCESSING; RADIATION SOURCES; RESOLUTION; SENSE ORGANS