Tube degradation experience and maintenance of steam generator

  • 1. Kyushu Electric Power Co., Inc., Fukuoka (Japan)

Description

This paper introduces steam generator degradation experience in Japan, our company's control of foreign objects during manufacturing, installations and outage, and techniques for removal of sludge accumulated on the secondary side of the SG. 7 figs

Part of:
The 19th KAIF-JAIF seminar on nuclear industry, September 29-30, 1997, Seoul, Korea

Additional details

Publishing Information

Publisher
KAIF.
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
The 19th KAIF-JAIF seminar on nuclear industry, September 29-30, 1997, Seoul, Korea
Imprint Pagination
385 p.
Journal Page Range
p. 135-157.

Conference

Title
19. KAIF-JAIF seminar on nuclear industry.
Dates
29-30 Sep 1997.
Place
Seoul (Korea, Republic of).

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
29017259
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
EDDY CURRENT TESTING; PLUGGING; SECONDARY COOLANT CIRCUITS; SLEEVES; SLUDGES; STEAM GENERATORS; STRESS CORROSION; TUBES
Descriptors DEC
BOILERS; CHEMICAL REACTIONS; COOLING SYSTEMS; CORROSION; ELECTROMAGNETIC TESTING; MATERIALS TESTING; NONDESTRUCTIVE TESTING; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; TESTING; VAPOR GENERATORS