The 8-GeV transfer line injection into main ring
Description
Included in this report are a brief review of the design lattice of the 8-GeV beam transfer line and the Main Ring, the recent measurements on the 8-GeV line lattice function as well as that of the Main Ring at 8-GeV. The injection matching is a very important part of the MR operation. Mismatches such as energy, timing, or position are easily corrected because they cause oscillations which are visible on the Turn-By-Turn (TBT) TV monitor display. Mis-matches due to beta and dispersion functions are detected only by using the Flying Wire or by doing measurements during beam study. A new method which makes use of the available data from TBT hardware was used to obtain the beam phase space ellipse. Data taken from Main Ring at injection gives the beta function needed for transfer matching from 8-GeV line. The result of this measurement is also presented here
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE95016697; NTIS; US Govt. Printing Office Dep.Files
27005665.pdf
Files
(1.5 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:2bad28d6c0849c4e35eff2a719562a60
|
1.5 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 24 p.
- Report number
- FNAL--TM-1923
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27005665
- Subject category
- S43: PARTICLE ACCELERATORS; S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM DYNAMICS; BEAM EMITTANCE; BEAM INJECTION; BEAM MONITORING; BEAM POSITION; BEAM TRANSPORT; DESIGN; DISPERSION RELATIONS; FERMILAB ACCELERATOR; MAGNETIC FIELD CONFIGURATIONS; PARTICLE BOOSTERS; PHASE SPACE
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; DYNAMICS; MATHEMATICAL SPACE; MECHANICS; MONITORING; SPACE; SYNCHROTRONS
Optional Information
- Contract/Grant/Project number
- Contract AC02-76CH03000
- Funding organization
- USDOE, Washington, DC (United States).