Estimation of the transit dose component in high dose rate brachytherapy
Creators
- 1. Servicio de Fisica y P.R., Hospital Clinico U, 'Lozano Blesa', Zaragoza (Spain)
Description
Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author)
Abstract (Spanish)
Los sistemas de planificacion asociados a equipos de alta tasa de dosis (HDR) suelen calcular la dosis suponiendo que la unica contribucion se debe a cuando la fuente se encuentra en las diferentes posiciones de parada (componente estacionaria), sin tener en cuenta la dosis suministrada cuando la fuente esta en movimiento (componente dinamica o de transito). La magnitud de la dosis en transito depende fundamentalmente de la velocidad de la fuente, la geometria del implante, la actividad de la fuente y la dosis prescrita, y, en determinadas aplicaciones de Alta Tasa esta dosis puede llegar a ser significativa en cuanto al incremento de potenciales complicaciones tardias en los tejidos sanos, y su estimacion esta recomendada en los protocolos de verificacion [1]. El proposito de este trabajo ha sido establecer una sistematica de calculo de la componente de transito de la dosis, para el equipo Gammamed 12i existente en el Servicio de RT del HCU de Zaragoza. Se ha desarrollado un programa de calculo y los resultados de dosis entrada-salida calculados se han comparado con medidas hechas con TLD en puntos discretos. (author)Additional details
Identifiers
Publishing Information
- Imprint Title
- Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers
- Imprint Pagination
- [928 p.]
- Journal Issue
- no. 7/CD
- Series
- C and S papers series
- Journal Page Range
- [4 p.]
- ISSN
- 1562-4153
- Report number
- IAEA-CSP--7/CD
Conference
- Title
- International conference on radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy
- Dates
- 26-30 Mar 2001
- Place
- Malaga (Spain)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 32065416
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- EVALUATION; PATIENTS; RADIATION DOSES; RADIATION MONITORING; RADIATION PROTECTION; RADIATION SOURCE IMPLANTS; RADIOTHERAPY; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY
- Descriptors DEC
- DOSEMETERS; DOSES; DOSIMETRY; IMPLANTS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MEDICINE; MONITORING; NUCLEAR MEDICINE; RADIATION SOURCES; RADIOLOGY; THERAPY
Optional Information
- Notes
- 3 refs, 3 figs Imprint:Data in PDF format; Acrobat Reader for Windows 3.x, 95, 98, NT 3.5.1, NT 4.0, MacIntosh and UNIX (SUN, HP, IRIX (SGI), AIX and Digital UNIX) included
- Secondary number(s)
- IAEA-CN--85-173