Published December 1, 2003 | Version v1
Journal article

Comparison of Two Concepts: Multi-Cavity Versus Clustered-Cavity Gyroklystrons

  • 1. Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, Maryland 20742 (United States)

Description

A comparative analysis between conventional four-cavity and three-stage clustered-cavity gyroklystrons is performed. The efficiency, gain and bandwidth of each scheme are analyzed. The results show that the conventional tube has a slightly higher efficiency, however the clustered-cavity scheme has an advantage in its bandwidth properties, gain and the gain-bandwidth product

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
691
Journal Issue
1
Journal Page Range
p. 378-385
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
6. workshop on high energy density and high power RF
Dates
22-26 Jun 2003
Place
Berkeley Springs, WV (United States)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
36068890
Subject category
S43: PARTICLE ACCELERATORS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCELERATORS; CAVITIES; COMPARATIVE EVALUATIONS; CONTROL; EFFICIENCY; ELECTROMAGNETISM; GAIN; KLYSTRONS; MICROWAVE AMPLIFIERS; PARTICLE BEAMS; RF SYSTEMS
Descriptors DEC
AMPLIFICATION; AMPLIFIERS; BEAMS; ELECTRON TUBES; ELECTRONIC EQUIPMENT; EQUIPMENT; EVALUATION; MAGNETISM; MICROWAVE EQUIPMENT; MICROWAVE TUBES

Optional Information

Notes
(c) 2003 American Institute of Physics