Published July 21, 2002
| Version v1
Journal article
Comment on 'Perspectives of medical X-ray imaging'
Description
In the paper 'Perspectives of medical X-ray imaging' (Nucl. Instr. and Meth. A 466 (2001) 99) the authors infer, from simple approximations, that the use of HOPG monochromator has no advantage in mammography compared to existing systems. We show that in order to compare imaging properties of different X-ray sources it is necessary to evaluate the spectra after the attenuation of the tissue to be imaged. Indeed, quasi-monochromatic X-ray sources have the potential to enhance image contrast and to reduce patient dose
Additional details
Identifiers
- PII
- S0168900202008914;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 487
- Journal Issue
- 3
- Journal Page Range
- p. 685-687
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 34008258
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- IMAGES; MAMMARY GLANDS; MEDICINE; X-RAY DETECTION; X-RAY SOURCES
- Descriptors DEC
- BODY; DETECTION; GLANDS; ORGANS; RADIATION DETECTION; RADIATION SOURCES
Optional Information
- Copyright
- Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.