Electrostatic design of the barrel CRID [Cherenkov Ring Imaging Detector] and associated measurements

Description

We report on the electrostatic design and related measurements of the barrel Cherenkov Ring Imaging Detector for the Stanford Large Detector experiment at the Stanford Linear Accelerator Center Linear Collider. We include test results of photon feedback in TMAE-laden gas, distortion measurements in the drift boxes and corona measurements. 13 refs., 21 figs

Availability note (English)

MF available from INIS under the Report Number; NTIS, PC A02/MF A01 as DE90010182; OSTI; INIS; US Govt. Printing Office Dep.

Files

21068404.pdf

Files (389.5 kB)

Name Size Download all
md5:8d87e8ba5f54982bb6191205a6412c2c
389.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
10 p.
Report number
SLAC-PUB--5214

Conference

Title
5. international conference on instrumentation for colliding beam physics.
Dates
15-21 Mar 1990.
Place
Novosibirsk (USSR).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
21068404
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CHERENKOV COUNTERS; CORONA DISCHARGES; ELECTRON DETECTION; ELECTROSTATICS; SPECIFICATIONS; STANFORD LINEAR COLLIDER; TESTING
Descriptors DEC
ACCELERATORS; CHARGED PARTICLE DETECTION; DETECTION; ELECTRIC DISCHARGES; LINEAR ACCELERATORS; MEASURING INSTRUMENTS; RADIATION DETECTION; RADIATION DETECTORS

Optional Information

Contract/Grant/Project number
Contract AC03-76SF00515; Grant PHY88-13669; Grant PHY88-13018
Secondary number(s)
CONF-9003150--3.