Published November 1, 1984 | Version v1
Journal article

Measurements of covariance for cascading gamma rays

  • 1. State Univ. of New York, Binghamtom (USA). Dept. of Physics, Applied Physics and Astronomy

Description

An apparatus has been developed to measure covariance and delayed covariance of the counting rates of detectors of the separate members of gamma ray cascades. This method offers advantages over conventional time coincidence measurements, particularly for long lived intermediate nuclear states. The method has been used to measure the half-life of the 304 keV level (16.9 +- 0.6 ms) and anisotropy (0.543 +- 0.002) of the 121-280 keV gamma cascade in 75As produced by the radioactive decay of 75Se. Other applications are discussed. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
227
Journal Issue
1
Series
CODEN: NIMRD.;Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
103-107
ISSN