Published March 1997 | Version v1
Report Open

The large-scale vented combustion test facility at AECL-WL: description and preliminary test results

  • 1. Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada)

Description

Implementation of hydrogen mitigation systems in nuclear reactor containments requires testing the effectiveness of the mitigation system, reliability and availability of the hardware, potential consequences of its use and the technical basis for hardware placement, on a meaningful scale. Similarly, the development and validation of containment codes used in nuclear reactor safety analysis require detailed combustion data from medium- and large-scale facilities. A Large-Scale Combustion Test Facility measuring 10 m x 4 m x 3 m (volume, 120 m3 ) has been constructed and commissioned at Whiteshell Laboratories to perform a wide variety of combustion experiments. The facility is designed to be versatile so that many geometrical configurations can be achieved. The facility incorporates extensive capabilities for instrumentation and high speed data acquisition, on-line gas sampling and analysis. Other features of the facility include operation at elevated temperatures up to 150 degrees C, easy access to the interior, and remote operation. Initial thermodynamic conditions in the facility can be controlled to within 0.1 vol% of constituent gases. The first series of experiments examined vented combustion in the full 120 m3-volume configuration with vent areas in the range of 0.56 to 2.24 m2 . The experiments were performed at ∼27 degrees C and near-atmospheric pressures, with hydrogen concentrations in the range of 8 to 12% by volume. This paper describes the Large-Scale Vented Combustion Test Facility and preliminary results from the first series of experiments. (author)

Files

31010399.pdf

Files (625.8 kB)

Name Size Download all
md5:6aeb44cde580dbada65f7b847e230bc6
625.8 kB Preview Download
Part of:
Proceedings of the OECD/NEA/CSNI workshop on the implementation of hydrogen mitigation techniques

Additional details

Publishing Information

ISBN
0-660-16916-9
Imprint Title
Proceedings of the OECD/NEA/CSNI workshop on the implementation of hydrogen mitigation techniques
Imprint Pagination
587 p.
Journal Page Range
p. 219-233
Report number
AECL--11762

Conference

Title
OECD/NEA/CSNI workshop on the implementation of hydrogen mitigation techniques
Dates
13-15 May 1996
Place
Winnipeg, MB (Canada)

Optional Information

Notes
11 refs., 12 figs.
Secondary number(s)
NEA/CSNI/R--96/8