Reliable one dimensional 46-CPWTR model applied to two dimensional heat transfer problem of insulated triangular duct
Creators
- 1. Department of Mechanical Engineering, Kun-Shan University of Technology, 949, Da-Wan Road, Yung-Kang City, Tainan County, Taiwan 710, Taiwan (China)
Description
In this study, the heat transfer characteristics of an insulated long triangular duct are analyzed by using the one dimensional plane wedge thermal resistance (PWTR) and plate thermal resistance (PTR) models. It is found that the errors produced by the PWTR model are all positive, but the errors produced by the PTR model are all negative. Thus, the combined plate wedge thermal resistance (CPWTR) model generated by paralleling PWTR and PTR models with the proportion factors of α = 0.4 vs. β = 0.6 (46-CPWTR model) is capable of neutralizing the positive and negative errors and returning very accurate results in comparison with the two dimensional numerical solutions analyzed by CFD software. The errors generated by the one dimensional 46-CPWTR model are within 1% for practical insulation thickness (t/R2 < 0.5). In the rare situations of thicker insulation (0.5 ≤ t/R2 ≤ 2), most of the errors returned by the one dimensional 55-CPWTR model are within 2%. Thus, engineers can obtain very reliable heat transfer results by applying the one dimensional 46-CPWTR or 55-CPWTR models to an insulated triangular duct. Meanwhile, the PTR model can still be used to estimate the highest surface temperature for a hot fluid duct or the lowest surface temperature for a cool fluid duct
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2007.01.036Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2007.01.036;
- PII
- S0196-8904(07)00056-8;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 48
- Journal Issue
- 12
- Journal Page Range
- p. 3135-3145
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39094026
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; COMPUTER CODES; DUCTS; ERRORS; FLUIDS; HEAT TRANSFER; MATHEMATICAL MODELS; NUMERICAL SOLUTION; ONE-DIMENSIONAL CALCULATIONS; PLATES; SURFACES; THICKNESS; TWO-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- DIMENSIONS; ENERGY TRANSFER; EVALUATION; MATHEMATICAL SOLUTIONS
Optional Information
- Copyright
- Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.