Pre-treatment of non-processing low level radioactive wastewater by coagulant technology
- 1. China Institute of Atomic Energy, P.O.Box 275(2), Beijing (China)
Description
The characteristics of non-processing low level radioactive wastewater (LLRW) in reprocessing industrial demonstration plant and reprocessing plant were large of count, complex composition, and more types of contaminated nuclides. The feasibility of using coagulant was investigated based on the characteristics of non-processing LLRW of reprocessing plant in this paper. Three coagulants were investigated for the removal of TOC in non-processing LLRW using NPAM as coagulant aids. Through orthogonal experiment, the influencing factors of coagulant result were probed in the work. The results show that the PAC is most effective to simulated non-processing LLRW; the dosage of coagulant is the major factor influencing the coagulant result. When the dosages of coagulant and coagulant aids are 348 mg/L and 24 μg/L respetively, the coagulation time is 30 min, and pH = 5, the optimal scheme for removing TOC in non-processing LLRW is obtained. And the removal efficiency of TOC reaches 24%. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Nuclear and Radiochemistry
- Journal Volume
- 42
- Journal Issue
- 5
- Journal Page Range
- p. 344-348
- ISSN
- 0253-9950
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 55094794
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
- Descriptors DEI
- COAGULANTS; LOW-LEVEL RADIOACTIVE WASTES; PH VALUE; REMOVAL; SIMULATION; WASTE WATER
- Descriptors DEC
- DRUGS; HEMATOLOGIC AGENTS; HYDROGEN COMPOUNDS; LIQUID WASTES; MATERIALS; OXYGEN COMPOUNDS; RADIOACTIVE MATERIALS; RADIOACTIVE WASTES; WASTES; WATER
Optional Information
- Notes
- 7 tabs., 12 refs.; http://dx.doi.org/10.7538/hhx.2020.YX.2019081