Published June 2009 | Version v1
Miscellaneous

Repetitive driving tests on electric wires used in UHV chambers

  • 1. Accelerator Engineering Corporation, Chiba (Japan)
  • 2. Toyama Company Limited, Zama, Kanagawa (Japan)
  • 3. Kyoto University, Institute for Chemical Research, Uji, Kyoto (Japan)

Description

In a vacuum system of an accelerator, a lot of moving devices are utilized attached with electric wires used for monitoring of a beam-signal, high-voltage and so on. For application of those wires in an ultra-high vacuum chamber, the lifetime of these wires under repetitive operation is a very important item. Six types of wires, four of which are covered with ceramic beads, are tested to examine their lifetimes under repetitive operation. From the results, most recommended wire is the stranded one with silver plated cupper wires, the lifetime of which is more than 50 thousand times. In the present paper, the detailed results of such experimental tests for various wires are reported. (author)

Part of:
Proceedings of the eleventh symposium on accelerator and related technology for application

Additional details

Publishing Information

Imprint Title
Proceedings of the eleventh symposium on accelerator and related technology for application
Imprint Pagination
95 p.
Journal Page Range
p. 79-82

Conference

Title
11. symposium on accelerator and related technology for application
Acronym
ARTA 2009
Dates
11-12 Jun 2009
Place
Tokyo (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
41062935
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; CONTAINERS; COPPER; ELECTRICAL INSULATORS; FAILURES; LIFETIME; PERFORMANCE TESTING; PLATING; PRESSURE RANGE NANO PA; VACUUM SYSTEMS; WIRES
Descriptors DEC
DEPOSITION; ELECTRICAL EQUIPMENT; ELEMENTS; EQUIPMENT; METALS; PRESSURE RANGE; SURFACE COATING; TESTING; TRANSITION ELEMENTS

Optional Information