Published July 1991 | Version v1
Journal article

DSP read-out of ADC'S for the H1 calorimeter

Creators

  • 1. CEN-Saclay, 91 - Gif-sur-Yvette (France). Dept. de Physique des Particules Elementaires

Description

This paper describes the essential features of the DSP board which is the heart of the H1 calorimeter acquisition system. The board performs among other tasks, on-line corrections to the data and zero suppression. The requirements, the main features of the design and the performance are discussed. The software programs that run in this board are briefly described. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Physics. B, Proceedings Supplements
Journal Volume
23A
Series
Nucl. Phys., B Proc. Suppl.
Journal Page Range
186-190
ISSN
0920-5632
CODEN
NPBSE

Conference

Title
2. international conference on advanced technology and particle physics.
Dates
11-15 Jun 1990.
Place
Como (Italy).