Published October 1, 1996 | Version v1
Journal article

A novel ASIC for readout electronics in semiconductor γ-ray detection

  • 1. CEA Centre d'Etudes Nucleaires de Grenoble, 38 (France). Lab. d'Electronique et de Technologie de l'Informatique
  • 2. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service d'Astrophysique

Description

A low-power low-noise multichannel integrated circuit is implemented in 1.2 μm CMOS technology. This circuit is designed for space γ-ray spectrometer using arrays of CdTe radiation detectors in the 20-750 keV range. The space environment needs rad-tolerant specifications for the technology like 20 krad of total integrated dose and consumption limited to 2 mW/channel. Each channel includes a low-noise charge-sensitive preamplifier, fitted band-pass filters, peak amplitude and rise-time measurements; these enable a remote rise-time corrected γ-ray energy spectral analysis. The circuit includes an associated logic block, dedicated to the internal timing, functional organization, external communication and data transfer. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
380
Journal Issue
1-2
Journal Page Range
p. 342-345.
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
9. international workshop on room temperature semiconductor X- and gamma-ray detectors, associated electronics and applications.
Dates
18-22 Sep 1995.
Place