Determination of urea 13C in urea 13C mixed powder by HPLC

  • 1. National Institute for the Control of Pharmaceutical and Biological Products, Beijing (China)

Description

A HPLC method is developed for determination of Urea 13C in Urea 13C Mixed Powder. A Alltech Econosphere NH2 column (250 mm x 4.6 mm, 5 μm)is used as stationary phrase, a mixture of V(acetonitrile): V(methanol): V(water) = 900 : 100: 10 is used as mobile phase and the flow rate is l mL·min-1, UV detection wavelength is performed at 200 nm. The calibration curve shows good linearity in the range of 0.2-1.0 g·L-1 of Urea 13C, y=2.548 x 106 x + 4.005 x 104, r=0.9999, and the averaged recovery is 100.6%. The method is simple and accurate, and can be used for the quality control of Urea 13C Mixed Powder. (authors)

Additional details

Publishing Information

Journal Title
Journal of Isotopes
Journal Volume
19
Journal Issue
4
Journal Page Range
p. 246-248
ISSN
1000-7512

Optional Information

Notes
2 figs., 1 ref.