Process pump operating problems and equipment failures, F-Canyon Reprocessing Facility, Savannah River Plant

Description

A compilation of operating problems and equipment failures associated with the process pumps in the Savannah River Plant F-Canyon Fuel Reprocessing Facility is presented. These data have been collected over the 30-year operation of the facility. An analysis of the failure rates of the pumps is also presented. A brief description of the pumps and the data bank from which the information was sorted is also included

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01; 1 as DE87006357.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
47 p.
Report number
DP--1731

INIS

Optional Information

Notes
Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted.