Published December 1, 2019 | Version v1
Journal article

Performance comparison of two signal multiplexing readouts for SiPM-based pet detector

  • 1. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055 (China)

Description

PET scanners using SiPMs as photodetectors could have tens of thousands of SiPMs. To simplify the readout electronics, analog signal multiplexing readouts are always preferred to be used as early as possible. In this paper, two simple analog signal multiplexing readouts, a capacitive charge-division readout, and a resistive charge-division readout were evaluated and compared using dual-ended readout detectors based on 10  ×  10 arrays of SensL MicroFJ-30035 SiPMs coupled to both ends of a 20  ×  20 LYSO array with a pitch size of 1.5 mm and a length of 20 mm. The performance of the detectors were evaluated at different bias voltages (from 27.0 V to 30.5 V with an interval of 0.5 V) and a temperature of 22.8 °C. The flood histograms show that all the crystals in the LYSO array were clearly identified, whilst better flood histogram was obtained using the resistive charge-division readout. At a bias voltage of 29.5V, the flood histogram quality, energy resolution, DOI resolution, and timing resolution of the detector obtained using the capacitive charge-division readout were 3.28  ±  0.85, 18.9%  ±  6.2%, 1.93  ±  0.20 mm, 1.25  ±  0.11 ns respectively, and those obtained using the resistive charge-division readout were 3.57  ±  0.81, 16.9%  ±  6.5%, 1.96  ±  0.23 mm and 1.23  ±  0.07 ns, respectively. Overall, the detector with the resistive charge-division readout provided better performance. (note)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6560/ab5738

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
64
Journal Issue
23
Journal Page Range
[11 p.]
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52004153
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ELECTRIC POTENTIAL; ENERGY RESOLUTION; FLOODS; POSITRON COMPUTED TOMOGRAPHY; READOUT SYSTEMS; SIGNALS
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; RESOLUTION; TOMOGRAPHY