Published 1972
| Version v1
Report
Restricted
Calibration of the experimental BND personnel neutron dosimeter for general use
Description
The experimental Brookhaven neutron dosimeter, BND, is a composite damage track and thermoluminescent detector. Thorium fission is used to respond to greater than 1 MeV and high sensitivity TLD 600 and 700 ribbons respond to softer neutrons. Previous experimental work at the Alternating Gradient Synchrotron, AGS, a 33 GeV proton accelerator, utilized the energy dependence of the ratio of thermoluminescent to Thorium response, softness. Softness variation was related to a correction factor used to adjust a TLD response to properly account for the dose equivalent. Calibration data for the BND for soft reactor spectra are presented. (U.S.)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- 25 p.
- Report number
- BNL--20100
Conference
- Title
- 5. ERDA workshop on personnel neutron dosimetry.
- Dates
- 6 May 1975.
- Place
- Washington, District of Columbia, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 7224028
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; DIELECTRIC TRACK DETECTORS; DOSE EQUIVALENTS; ENERGY DEPENDENCE; FISSION FOIL DETECTORS; NEUTRON DOSIMETRY; PERSONNEL DOSIMETRY; RESPONSE FUNCTIONS; SENSITIVITY; THERMOLUMINESCENT DOSEMETERS; THORIUM
- Descriptors DEC
- ACTINIDES; DOSEMETERS; DOSIMETRY; ELEMENTS; FUNCTIONS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; METALS; NEUTRON DETECTORS; RADIATION DETECTORS
Optional Information
- Secondary number(s)
- CONF-750551--1.