Description

Highlights: •We designed the cryogenic experiment to test the Nb3Sn superconducting magnet performance in the low temperature. •We measured the pressure drop in CICC of Nb3Sn superconducting magnet at 5 K. •We corrected Katheder's formula and given the corrected correlation. •The curve of per meter pressure drop in the CICC of Nb3Sn superconducting magnet was given. -- Abstract: In order to test the performance of experimental advanced superconducting tokamak (EAST) central solenoid (CS) model coil, which was made by the cable-in-conduit conductor using Nb3Sn strands and a 316 L stainless steel jacket, a cryogenic experiment system was designed. The experimental results showed that the superconducting magnet was cooled down to 5 K, which could meet the test requirements successfully. Meanwhile, we measured the pressure drop in CICC of Nb3Sn superconducting magnet under the circulating mode of forced flow cooling which used supercritical helium as coolant compared with the result calculated by the Katheder fraction factor correlation, it showed that calculated pressure drop underestimates the experimental data. We corrected the Katheder correlation and compared with the experimental data, it proved that the corrected correlation is much more suitable for the kind of CICC of Nb3Sn superconducting magnet

Availability note (English)

Available from http://dx.doi.org/10.1016/j.physc.2013.11.004

Additional details

Identifiers

DOI
10.1016/j.physc.2013.11.004;
PII
S0921-4534(13)00445-0;

Publishing Information

Journal Title
Physica. C, Superconductivity
Journal Volume
497
Journal Page Range
p. 58-61
ISSN
0921-4534
CODEN
PHYCE6

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.