Published 1989 | Version v1
Book

Effectiveness of the containment spray system

  • 1. Institute for Electrical Power Research (VEIKI), Budapest (Hungary)

Description

The efficiency of the spray system of Paks NPP Unit No. 1. have been determined based on experimental measurements and on the results of two different calculation methods. The curve represents relationship between the mass flow rate of spray system and the duration of overpressure following design basis accident (LB LOCA) within the containment. Using them, for given tightness of the containment, a correct estimation can be given for radioactivity released into the environment. (orig.)

Additional details

Publishing Information

Publisher
Braun.
Imprint Place
Karlsruhe (Germany, F.R.)
ISBN
3-7650-1116-9
Imprint Title
Fourth international topical meeting on nuclear reactor thermal-hydraulics (NURETH-4). Proceedings. Vol. 2
Imprint Pagination
696 p.
Journal Page Range
p. 938-942.

Conference

Title
4. international topical meeting on nuclear reactor thermal-hydraulics (NURETH-4).
Dates
10-13 Oct 1989.
Place
Karlsruhe (Germany, F.R.).