Published May 2014 | Version v1
Miscellaneous

Development of a Temperature Compensation Method for the Radiation Detector of a Radiation Monitoring System

  • 1. Pusan National Univ. Busan (Korea, Republic of)

Description

Americium, which has been used to date for the assessment of integrity and efficiency of the radiation detector, was replaced by an LED to resolve these problems. However, while americium is negligibly affected by the temperature and the surrounding environment, the LED is significantly affected by the temperature. Accordingly, a method to resolve this issue is needed. In this study, a temperature-compensated preamplifier was developed, where the reference luminous output of the LED affecting on temperatures is constantly maintained to be uniform by controlling the current and the PMT gain difference is compensated by controlling the high voltage from a comparison of the input and output pulse values. After setting up the experimental apparatus, the validity of the preamplifier was verified through radiation measurement experiments where the temperature was varied from 10 .deg. C to 60 .deg. C. The output signals of the scintillation detector of the RMS are intricately related to the temperature. In particular, the output signal value is greatly affected by the thermal equilibrium in the process of converting electro-magnetic energy to light energy and back to electrical energy. To compensate for these temperature characteristics, the americium standard source is used, since it is not affected by temperature, or a temperature compensation method using an LED optical-pulse as a reference value is used. In this study, instead of the americium standard source, an LED and a temperature detector were used to develop a temperature compensation device for the PMT amplification factor. To verify the validity of the developed method, a reference temperature of 25 .deg. C and a reference current of a 60μA LED optical-pulse were used to experimentally measure the radiation while varying the temperature from 10 .deg. C to 60 .deg. C using a Cs-137 standard source. The experiment results showed that the measurement error is reduced by approximately 83.3 % by using the temperature compensation

Part of:
Proceedings of the KNS 2014 spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS 2014 spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[4 p.]

Conference

Title
2014 spring meeting of the KNS
Dates
28-30 May 2014
Place
Jeju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
46050840
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
EFFICIENCY; EQUILIBRIUM; MONITORING; PHOSPHORS; RADIATION DETECTORS; RADIATIONS; REGULATIONS; VALIDATION
Descriptors DEC
LAWS; MEASURING INSTRUMENTS; TESTING

Optional Information

Notes
7 refs, 7 figs