Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging
Creators
- 1. Department of Radiation Oncology, The Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)
Description
Purpose: To quantify set-up uncertainties during voluntary deep inspiration breath hold (DIBH) radiotherapy using 3D-surface imaging in patients with left sided breast cancer. Material and methods: Nineteen patients were included. Cone-beam CT-scan (CBCT) was used for online set-up correction while patients were instructed to perform a voluntary DIBH. The reproducibility of the DIBH during treatment was monitored with 2D-fluoroscopy and portal imaging. Simultaneously, a surface imaging system was used to capture 3D-surfaces throughout CBCT acquisition and delivery of treatment beams. Retrospectively, all captured surfaces were registered to the planning-CT surface. Interfraction, intra-fraction and intra-beam set-up variability were quantified in left–right, cranio–caudal and anterior–posterior direction. Results: Inter-fraction systematic (Σ) and random (σ) translational errors (1SD) before and after set-up correction were between 0.20–0.50 cm and 0.09–0.22 cm, respectively, whereas rotational Σ and σ errors were between 0.08 and 1.56°. The intra-fraction Σ and σ errors were ⩽0.14 cm and ⩽0.47°. The intra-beam SD variability was ⩽0.08 cm and ⩽0.28° in all directions. Conclusion: Quantification of 3D set-up variability in DIBH RT showed that patients are able to perform a very stable and reproducible DIBH within a treatment fraction. However, relatively large inter-fraction variability requires online image guided set-up corrections
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radonc.2012.12.016Additional details
Identifiers
- DOI
- 10.1016/j.radonc.2012.12.016;
- PII
- S0167-8140(13)00004-2;
Publishing Information
- Journal Title
- Radiotherapy and Oncology
- Journal Volume
- 106
- Journal Issue
- 2
- Journal Page Range
- p. 225-230
- ISSN
- 0167-8140
- CODEN
- RAONDT
INIS
- Country of Publication
- Ireland
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45079642
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPUTERIZED TOMOGRAPHY; CORRECTIONS; ERRORS; FLUOROSCOPY; IMAGE PROCESSING; IMAGES; MAMMARY GLANDS; NEOPLASMS; PATIENTS; RADIOTHERAPY
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; BODY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY; THERAPY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.