The comparative analysis of model and prototype test results of Bulb turbine
Creators
- 1. Faculty of Mechanical Engineering, Belgrade University Kraljice Marije 16, Belgrade, 11000 (Serbia)
- 2. Hydropower Plant Djerdap Pop Stojanova 2, Belgrade, 11000 (Serbia)
Description
This paper presents the problem of the hydropower plant oblique water inflow and its influence on the turbines operation. Oblique water inflow on the low head hydropower plant with bulb turbines influences turbine characteristics. The characteristics change occurs due to swirl incidence in the turbine inlet which spreads to the guide vanes inlet. Downstream, the flow conditions change is caused in the turbine runner in relation to the flow conditions without swirl inflow. Special attention is paid to the phenomenon of swirl flow incidence in the turbine conduit. With the aim of presenting and analyzing the oblique water inflow consequences on the hydropower plant operation, the existing turbine model tests results, performed in the laboratories, and the in situ prototype testing results have been used.
Availability note (English)
Available from http://dx.doi.org/10.1088/1755-1315/12/1/012091Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series: Earth and Environmental Science (EES)
- Journal Volume
- 12
- Journal Issue
- 1
- Journal Page Range
- [9 p.]
- ISSN
- 1755-1315
Conference
- Title
- 25. IAHR symposium on hydraulic machinery and systems
- Dates
- 20-24 Sep 2010
- Place
- Timisoara (Romania)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42066368
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- HYDROELECTRIC POWER PLANTS; OPERATION; TESTING; TURBINES; VANES; VORTEX FLOW; WATER
- Descriptors DEC
- EQUIPMENT; FLUID FLOW; HYDROGEN COMPOUNDS; MACHINERY; OXYGEN COMPOUNDS; POWER PLANTS; TURBOMACHINERY