Published October 1, 1980 | Version v1
Journal article

Multi-step avalanche chambers for FNAL experiment E605

  • 1. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Physique des Particules Elementaires
  • 2. State Univ. of New York, Stony Brook (USA)

Description

Physical processes in multi-step avalanche chambers, detector properties, and difficulties in operation are discussed. Advantages of multi-step chambers over classical MWPCs for specific experimental problems encountered in experiment E605 (high-flux environment and Cherenkov imaging) are described. Some details of detector design are presented. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods
Journal Volume
176
Journal Issue
1/2
Series
Nucl. Instrum. Methods.
Journal Page Range
233-238
ISSN
0029-554X

Conference

Title
Wire chamber conference.
Dates
27 - 29 Feb 1980.
Place
Vienna, Austria.

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
12592826
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CHERENKOV RADIATION; CONSTRUCTION; GAIN; IONIZATION CHAMBERS; MULTIWIRE PROPORTIONAL CHAMBER; PARTICLE TRACKS; RADIATION DETECTION
Descriptors DEC
ELECTROMAGNETIC RADIATION; MEASURING INSTRUMENTS; PROPORTIONAL COUNTERS; RADIATION DETECTORS; RADIATIONS