Design of a 8-kW refrigeration system for ITER common test

  • 1. Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan)

Description

The Japan Atomic Energy Research Institute is working on the detailed design of the helium refrigeration system (8 kW) for the Central Solenoid Model Coils which will be fabricated and tested in the International Thermonuclear Experimental Reactor (ITER) R and D project. The helium refrigeration system consists of a supercritical helium cryogenic pump unit, helium refrigerator/liquefier unit, etc. The design will take into consideration the various coil operation modes, refrigeration efficiency, economy, and research and development of the cryogenic components required for the ITER. (Author)

Additional details

Additional titles

Augmented title (English)
International Thermonuclear Experimental Reactor

Publishing Information

Journal Title
Cryogenics
Journal Volume
32
Journal Issue
ICEC suppl.
Journal Page Range
p. 60-63.
ISSN
0011-2275
CODEN
CRYOAX

Conference

Title
cryogenic engineering and superconductor technology.
Acronym
14. international cryogenic engineering conference and international cryogenic materials conference
Dates
8-12 Jun 1992.
Place
Kiev (Ukraine).

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
24028604
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CRYOPUMPS; DESIGN; HELIUM; ITER TOKAMAK; REFRIGERATION; REFRIGERATORS; SOLENOIDS; SUPERCONDUCTING MAGNETS
Descriptors DEC
CLOSED PLASMA DEVICES; COOLING; ELECTRIC COILS; ELECTRICAL EQUIPMENT; ELECTROMAGNETS; ELEMENTS; EQUIPMENT; MAGNETS; NONMETALS; PUMPS; RARE GASES; SUPERCONDUCTING DEVICES; THERMONUCLEAR DEVICES; TOKAMAK DEVICES; VACUUM PUMPS