Published March 2009 | Version v1
Journal article

A suggestion to enhance pool boiling heat transfer on a vertical tube surface

  • 1. Andong National University, Andong (Korea, Republic of)

Description

To find a way of improving pool boiling heat transfer on a vertical tube surface, a revised annulus has been investigated experimentally. The annulus with closed bottoms has a shorter outer tube than the inside heated tube. For the study, three tube diameters (16.5, 19.1, and 25.4mm) and water at atmospheric pressure were used. The annular gap covers from 3.2 to 19.3mm in size and is generated by several glass tubes, which are fabricated around the heated tube. To clarify effects of the revised annulus on heat transfer, experimental results of the annulus were compared to the data of unrestricted tubes. The heat transfer coefficients for the revised annulus increased remarkably in comparison to the unrestricted tube

Additional details

Publishing Information

Journal Title
Journal of Mechanical Science and Technology
Journal Volume
23
Journal Issue
3
Series
8 refs, 5 figs
Journal Page Range
p. 593-598
ISSN
1738-494X

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
43010528
Subject category
S42: ENGINEERING;
Descriptors DEI
HEAT TRANSFER; POOL BOILING; SURFACES; TUBES
Descriptors DEC
BOILING; ENERGY TRANSFER; PHASE TRANSFORMATIONS