Published November 1980
| Version v1
Report
Open
Ultrasonic shear wave velocity in CLF/CMT graphite from room temperature to 20000F
Description
The temperature dependence of the ultrasonic shear velocity in CLF/CMT graphite was determined from room temperature to 20000F using a pulse-echo technique. Data are presented for five 0.75-inch-diameter specimens all machined from the same CLF/CMT billet. Plots of ultrasonic pulse-echo radial and axial scans of the billet which characterize the material property uniformity of the billet are also given
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.Files
12591331.pdf
Files
(460.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:9adec5a65afe9764c633538d7d8bbf25
|
460.1 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 36 p.
- Report number
- SAND--80-1850
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12591331
- Subject category
- S36: MATERIALS SCIENCE;
- Descriptors DEI
- GRAPHITE; HIGH TEMPERATURE; MEDIUM TEMPERATURE; SHEAR; TEMPERATURE DEPENDENCE; ULTRASONIC TESTING; ULTRASONIC WAVES; VELOCITY; VERY HIGH TEMPERATURE
- Descriptors DEC
- ACOUSTIC TESTING; CARBON; ELEMENTS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; NONMETALS; SOUND WAVES; TESTING