Ultrasonic shear wave velocity in CLF/CMT graphite from room temperature to 20000F

Description

The temperature dependence of the ultrasonic shear velocity in CLF/CMT graphite was determined from room temperature to 20000F using a pulse-echo technique. Data are presented for five 0.75-inch-diameter specimens all machined from the same CLF/CMT billet. Plots of ultrasonic pulse-echo radial and axial scans of the billet which characterize the material property uniformity of the billet are also given

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

12591331.pdf

Files (460.1 kB)

Name Size Download all
md5:9adec5a65afe9764c633538d7d8bbf25
460.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
36 p.
Report number
SAND--80-1850

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12591331
Subject category
S36: MATERIALS SCIENCE;
Descriptors DEI
GRAPHITE; HIGH TEMPERATURE; MEDIUM TEMPERATURE; SHEAR; TEMPERATURE DEPENDENCE; ULTRASONIC TESTING; ULTRASONIC WAVES; VELOCITY; VERY HIGH TEMPERATURE
Descriptors DEC
ACOUSTIC TESTING; CARBON; ELEMENTS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; NONMETALS; SOUND WAVES; TESTING