A Schottky receiver for non-perturbative tune monitoring in the Tevatron

Description

Transverse Schottky noise and coherent betatron modulation of the bunched beam revolution harmonics are continuously monitored by a sensitive receiver. The electronics relies upon low noise amplifiers, narrow-band filters, and spectrally pure oscillators to obtain a minimum detectable signal of -160 dBm. Dynamic range is 80 dB. Separate baseband proton and antiproton signals are continuously analyzed in the Main Control Room

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - OSTI; 1 as DE89011453.

Files

20060751.pdf

Files (267.0 kB)

Name Size Download all
md5:7e7ca39e5c2b5fee11cfe18b040958e6
267.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
FNAL/C--89/73

Conference

Title
13. particle accelerator conference.
Dates
20-23 Mar 1989.
Place
Chicago, IL (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20060751
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM BUNCHING; BEAM MONITORING; BEAM MONITORS; ELECTRONIC CIRCUITS; FERMILAB TEVATRON; SCHOTTKY EFFECT; SPECIFICATIONS
Descriptors DEC
ACCELERATORS; BEAM DYNAMICS; CYCLIC ACCELERATORS; DYNAMICS; MEASURING INSTRUMENTS; MECHANICS; MONITORING; MONITORS; SYNCHROTRONS

Optional Information

Notes
Portions of this document are illegible in microfiche products.
Secondary number(s)
CONF-890335--94.