Published June 21, 2003 | Version v1
Journal article

Combinational use of conformal and intensity-modulated beams in radiotherapy planning

  • 1. Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

Description

Intensity-modulated (IM) beam profiles computed by inverse-planning systems tend to be complex and may have multiple spatial minima and maxima. In addition to the structure originating from the treatment objectives, beam profiles might contain stochastic structure or noise and numerical artefacts, which present certain practical difficulties. The combinational use of conformal and intensity-modulated beams could be a different method of making the total fluence distribution less noisy and deliverable without compromising the advantages of IMRT. The investigation of this possibility provided the basis for this paper. A treatment-planning study was performed to compare plans combining modulated and unmodulated beams with a 5-field, equally spaced, full IMRT plan for treating the prostate and seminal vesicles in three patients. Beam angles for this study were 0 deg., 72 deg., 144 deg., 216 deg. and 288 deg. Additionally, a study was performed on a patient with a different beam arrangement (36 deg., 108 deg., 180 deg., 252 deg., 324 deg.) from the first study to test the obtained results. This study has demonstrated that it is possible to substitute up to two conformal beams in the originally full IMRT plan when carefully selecting the conformal beam angles. Making the anterior beam (0 deg.) and an anterior oblique beam (between 0 deg. and 90 deg.) conformal leads to a reduction in the total number of monitor units and segments of about 15% and 39%, respectively. Additionally, these two open fields can be used for simpler treatment verification

Availability note (English)

Available online at http://stacks.iop.org/0031-9155/48/1795/m31209.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/

Additional details

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
48
Journal Issue
12
Journal Page Range
p. 1795-1807
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34049908
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BEAM MONITORING; BEAM POSITION; MODULATION; PLANNING; RADIOTHERAPY
Descriptors DEC
MEDICINE; MONITORING; NUCLEAR MEDICINE; RADIOLOGY; THERAPY