Published October 2012 | Version v1
Journal article

Reliability analysis of auxiliary feed water system (AFWS) at nuclear power plant by using GO-FLOW methodology

  • 1. Nuclear and Radiation Safety Center, MEP, Beijing (China)

Description

The GO-FLOW methodology has been applied to a reliability analysis of Auxiliary Feed Water System (AFWS) of Daya Bay nuclear power plant as an example which is time-related issue and has a complex operational behavior. In this paper, GO-FLOW chart was drawn according to the principle chart of AFWS, and the success probabilities of AFWS at different time points were calculated. The analysis results well explain that GO-FLOW could be well applicable to the analysis of PWR-AFWS, GO-FLOW has proved to be an effective and useful methodology in system reliability analysis, and it can provide technology support to the living risk monitoring system. (authors)

Additional details

Publishing Information

Journal Title
Radiation Protection Bulletin
Journal Volume
32
Journal Issue
5
Journal Page Range
p. 19-23
ISSN
1004-6356

Optional Information

Notes
3 figs., 2 tabs., 4 refs.