Characterization of a new photo-fluorescent film dosimeter for high-radiation dose applications
Creators
- 1. BATTELLE (PACIFIC NW LAB) (United States)
- 2. BATTELLE (PACIFIC NW LAB)(United States)
- 3. National Institute of Standards and Technology (United States)
Description
Characterization studies on one of the first versions of the Sunna fluorescent dosimeter have been published by Kovacs and McLaughlin. This present study describes testing results of a newer version of the dosimeter (Model and 61543;, batch 0399-20). This dosimeter is a 1-cm by 3-cm polymeric film of 0.5 mm thickness that emits a green fluorescence component at intensities almost linear with dose. The manufacturing method (injection molding) allows potential batch sizes on the order of a million while maintaining a signal precision on the order of+/- 1%. Studies include dose response, dose rate dependence, energy dependence, post-irradiation stability, environmental effects, and variation of response within a batch. Data for both food irradiation and sterilization dose levels were obtained. The results indicate that the green signal (0.3-200 kGy) works well for food irradiation dose levels, especially in refrigerated facilities that maintain tight temperature control. The green signal also works well in sterilization facilities because its irradiation temperature coefficient above room temperature is minimal at sterilization doses. If the user requires readout results in less than 22 hours after room temperature irradiation, the user can either calibrate for a specific post-irradiation readout time(s) or simply heat the dosimeters in a small laboratory oven to quickly stabilize the signal
Availability note (English)
Available from Pacific Northwest National Lab., Richland, WA (United States)Additional details
Publishing Information
- Imprint Pagination
- 4 p.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 35017822
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- ACCURACY; DOSE RATES; DOSEMETERS; FLUORESCENCE; FOOD PROCESSING; IRRADIATION; MANUFACTURING; PERFORMANCE TESTING; STERILIZATION
- Descriptors DEC
- EMISSION; LUMINESCENCE; MEASURING INSTRUMENTS; PHOTON EMISSION; PROCESSING; TESTING
Optional Information
- Contract/Grant/Project number
- AC06-76RL01830
- Notes
- Also published in: Radiation Physics and Chemistry, ISSN 0146-5724, v. 63(3-6) p. 751-754
- Funding organization
- US Department of Energy (United States)
- Secondary number(s)
- PNNL-SA--31595