The RELAP5/MOD3.1 code was used for the calculations. Conservatism of the analysis consisted in the choice of unfavourable conditions for reactor core cooling. 'Avoiding departure from nucleate boiling' was the principal acceptance criterion for the design basis accident. The departure from nucleate boiling ratio (DNBR) was evaluated by means of the standardized PI-1 correlation. The minimum DNBR attained, viz. 1.41, has a sufficient margin above the PI-1 correlation limit for the WWER fuel (1.29)

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic

Additional details

Additional titles

Original title (Czech)
Bezpecnostni analyzy pro nove palivo JE Dukovany - ztrata vnejsiho elektrickeho napajeni. Revize c. 1

Publishing Information

Imprint Pagination
57 p.
Report number
UJV--11003-T

Optional Information

Notes
22 figs., 17 refs.