Safety analyses for the new fuel at the Dukovany NPP. Blackout. Revision 1
Description
The RELAP5/MOD3.1 code was used for the calculations. Conservatism of the analysis consisted in the choice of unfavourable conditions for reactor core cooling. 'Avoiding departure from nucleate boiling' was the principal acceptance criterion for the design basis accident. The departure from nucleate boiling ratio (DNBR) was evaluated by means of the standardized PI-1 correlation. The minimum DNBR attained, viz. 1.41, has a sufficient margin above the PI-1 correlation limit for the WWER fuel (1.29)
Availability note (English)
Available from Nuclear Research Institute Rez, 250 68 Rez, Czech RepublicAdditional details
Additional titles
- Original title (Czech)
- Bezpecnostni analyzy pro nove palivo JE Dukovany - ztrata vnejsiho elektrickeho napajeni. Revize c. 1
Publishing Information
- Imprint Pagination
- 57 p.
- Report number
- UJV--11003-T
INIS
- Country of Publication
- Czech Republic
- Country of Input or Organization
- Czech Republic
- INIS RN
- 30058545
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- COMPUTER CALCULATIONS; DEPARTURE NUCLEATE BOILING; DESIGN BASIS ACCIDENTS; DUKOVANY-1 REACTOR; POWER LOSSES; R CODES; REACTOR SAFETY; RELIABILITY; SAFETY ANALYSIS
- Descriptors DEC
- ACCIDENTS; BOILING; COMPUTER CODES; ENERGY LOSSES; ENRICHED URANIUM REACTORS; NUCLEATE BOILING; PHASE TRANSFORMATIONS; POWER REACTORS; PWR TYPE REACTORS; REACTOR ACCIDENTS; REACTORS; SAFETY; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS
Optional Information
- Notes
- 22 figs., 17 refs.