Published August 23, 2005 | Version v1
Report Restricted

Vertical Drop of 44-BWR Waste Package With Lifting Collars

Description

The objective of this calculation is to determine the structural response of a waste package (WP) dropped flat on its bottom from a specified height. The WP used for that purpose is the 44-Boiling Water Reactor (BWR) WP. The scope of this document is limited to reporting the calculation results in terms of stress intensities. The Uncanistered Waste Disposal Container System is classified as Quality Level 1 (Ref. 4, page 7). Therefore, this calculation is subject to the requirements of the Quality Assurance Requirements and Description (Ref. 16). AP-3. 12Q, Design Calculations and Analyses (Ref. 11) is used to perform the calculation and develop the document. The information provided by the sketches attached to this calculation is that of the potential design of the type of 44-BWR WP considered in this calculation and provides the potential dimensions and materials for that design

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00899348; PURL: https://www.osti.gov/servlets/purl/899348-hJaYkN/

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
40 p.
Report number
US--000-00C-DSU0-00800-000-00A

Optional Information

Contract/Grant/Project number
MOL--20021015.0322; DC--33765
Notes
doi 10.2172/899348
Funding organization
US Department of Energy (United States)