Published 2022 | Version v1
Journal article

Investigation of photon attenuation factors for TeO2-Bi2O3–B2O3 glass systems using SRIM codes, EPICS2017 library and Phy-X/PSD

  • 1. Department of Nuclear Medicine Research, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman bin Faisal University (IAU), P.O. Box 1982, Dammam 31441 (Saudi Arabia)
  • 2. Department of Physics, Faculty of Science, Isra University, Amman (Jordan)
  • 3. Bandırma Onyedi Eylul University, Vocational School of Health Services, Medical Imaging Department, 10200, Balıkesir (Turkey)
  • 4. Department of Science and Technology – Philippine Nuclear Research Institute (DOST-PNRI), Commonwealth Avenue, Diliman, Quezon City 1101 (Philippines)

Description

We aimed to examine the photon shielding characteristics of the TeO2-Bi2O3-B2O3 ternary glass system using EPICS2017 library and Phy-X/PSD software. Seven glass systems, TeBiB1-TeBiB7, with varying TeO2, Bi2O3, and B2O3 compositions were examined. The mass attenuation coefficient (MAC) evaluated with EPICS2017 (MACEPICS2017) is slightly lower than MAC derived from Phy-X/PSD software (MACPhy-X/PSD) by an average of 0.24%. MACEPICS2017 is in good agreement with MACPhy-X/PSD at all the examined energies. Substituting an atom fraction of Bi2O3 with TeO2 and/or B2O3 resulted in the decrease of the total atomic cross-section of the glass, which in turn decreases the MAC. The linear attenuation coefficient (LAC) has comparatively higher values in the low energy zone (1.034–1.563 cm−1 at 0.347 MeV), and the lowest values were reported at 2.506 MeV (in order of 0.2 cm−1). TeBiB1 has relatively higher LAC than TeBiB2-TeBiB7 glasses, whereas TeBiB6 and TeBiB7 glasses have nearly the same LAC and they possess lower LAC than the remaining glasses. The half-value layer (HVL) at 0.347 MeV takes the following values: 0.443 cm for TeBiB1, 0.532 cm for TeBiB2, 0.537 cm for TeBiB3, 0.541 cm for TeBiB4, 0.545 cm for TeBiB5, 0.670 cm for TeBiB6 and 0.670 cm for TeBiB7. The sequence of HVL is TeBiB6 > TeBiB7 > TeBiB2 > TeBiB3 > TeBiB4 > TeBiB5 > TeBiB1. The tenth value layer results revealed that the TeBiB1- TeBiB7 samples are good attenuators to the low energetic radiation. We found that TeBiB1 has the thinnest TVL (equals 4.439 cm, at 0.826 MeV), while TeBiB6 has the thickest TVL. (author)

Availability note (English)

Available on-line: https://doi.org/10.1016/j.ijleo.2022.168832

Additional details

Identifiers

Publishing Information

Journal Title
Optik
Journal Volume
257
Journal Page Range
vp
ISSN
0030-4026

INIS

Country of Publication
Germany
Country of Input or Organization
Philippines
INIS RN
54095721
Subject category
S36: MATERIALS SCIENCE;
Descriptors DEI
BISMUTH OXIDES; BORATES; BORON OXIDES; CROSS SECTIONS; GLASS; PHOTONS; SHIELDING; TELLURIUM OXIDES
Descriptors DEC
BISMUTH COMPOUNDS; BORON COMPOUNDS; BOSONS; CHALCOGENIDES; ELEMENTARY PARTICLES; MASSLESS PARTICLES; OXIDES; OXYGEN COMPOUNDS; TELLURIUM COMPOUNDS

Optional Information

Notes
35 refs.